The contact angle dual transducers
The angle dual transducers have minimum "a dead zone", high signal-to-noise ratio
and a small x-value. All these characteristics allow to use transducers of this series for testing of
welded joints of various thin-walled objects, including in the presence of the reinforcing bead,
and as for testing of various elements metal structures, pipelines and other products made of
coarse-grained materials.
Transducers are made several standard sizes: for testing of large-sized details, standard (small-sized)
and tiny, with wedge from plexiglass and polyimide.
|
|
Standard transducers (small-sized)
|
ƒ,
MHz
|
Angle of
probe,
degree.
|
X-value, mm
|
Dimensions
piezoelectric element,
mm
|
Size
a contact
surface, mm
|
Dimensions
(HxSxL), mm
|
Designation
|
|
plexiglass
|
polyimede
|
| 5 |
65
|
6
|
4õ6 |
13õ16 |
18õ16õ20 |
|
P122-5-65-Ì |
| 70 |
6 |
|
P122-5-70-Ì |
| 10 |
65
|
5
|
4õ6 |
13õ16
|
18õ16õ20 |
|
P122-10-65-Ì
|
| 70 |
6 |
|
P122-10-70-Ì
|
Transducers for testing of large-sized details
|
ƒ,
MHz
|
Angle of
probe,
degree.
|
X-value, mm
|
Dimensions
piezoelectric element,
mm
|
Size
a contact
surface, mm
|
Dimensions
(HxSxL), mm
|
Designation
|
|
plexiglass
|
polyimede
|
| 2,5 |
65
|
16
|
10õ13 |
30õ35 |
23õ30õ40 |
P122-2,5-65-B
|
|
| 70 |
17 |
P122-2,5-70-B |
|
| 75 |
17 |
P122-2,5-75-B |
|
| 5 |
65
|
10
|
4õ8 |
16õ25
|
25õ18õ30 |
P122-5-65-Ñ
|
P122-5-65-PÑ
|
| 70 |
11 |
P122-5-70-Ñ |
P122-5-70-PÑ
|
| 75 |
12 |
P122-5-75-Ñ |
P122-5-75-PÑ |
Tiny transducers
|
ƒ,
MHz
|
Angle of
probe,
degree.
|
X-value, mm
|
Dimensions
piezoelectric element,
mm
|
Size
a contact
surface, mm
|
Dimensions
(HxSxL), mm
|
Designation
|
|
plexiglass
|
polyimede
|
|
5
|
65
|
5
|
4õ4 |
11õ15 |
12õ11õ16 |
|
P122-5-65-mm |
| 70 |
5 |
|
P122-5-70-mm |
|
65
|
4-5
|
4õ4 |
11õ15 |
8õ11õ16 |
|
P122-5-65-ÌÊ |
| 70 |
4-5 |
|
P122-5-70-ÌÊ |
| 10 |
65
|
5
|
4õ4 |
11õ15
|
12õ11õ16 |
|
P122-10-65-mm
|
| 70 |
5 |
|
P122-10-70-mm
|
|
65
|
4-5
|
4õ4 |
11õ15
|
8õ11õ16 |
|
P122-10-65-ÌÊ
|
| 70 |
4-5 |
|
P122-10-70-ÌÊ
|
|