Differential characteristic |
Technical Characteristics |
Field of utilization
UKVS-1 Inspection system for water content
|
Inspection system UKVS-1 is intended for non-destructive ultrasonic testing water content in cellular
airplane units IL-86, IL-96, IL-76, ÒU-204, ÀÍ-124 ("Ruslan"), etc., and also helicopters MI-28N,
ÌI-24 and so forth under operating conditions. The water which has got in units reduces durability of
glue joints, causes corrosion of a foil of honeycomb, leads to increase weight and to change
of centering of units and at water freezing - to a separation of a covering from cellular filler or to unit
destruction. The presence testing, definition of the locations and a quantity of water in glued cellular
designs of planes is one of the important problems in safety of flights of planes and helicopters.
|
Differential characteristic
- Use flaw detector UD2V-P46 or UD4-Ò as the high-precision measuring module;
- The testing is carried out, as on the units removed from the plane in the conditions of a hangar,
and are direct by the plane on periodic forms of maintenance service;
- Materials of coverings and honeycombs - as metals (aluminum, its alloys, etc.), and nonmetals -
composite materials;
- Thickness of coverings 0,4-2 mm, the size of cellular cells 2,5-5 mm;
- Locality of the testing - 5 mm, is found out water in a separate cellular cell;
- High sensitivity of a method - the minimum found out water level in a cellular cell - from 0,5 mm.
|
Basic Delivery Set
- Ultrasonic flaw detector UD2V-P46.LD or UD4-Ò ;
- Local immersion a bath;
- Industrial the high-frequency immersion transducer;
- The pump with system water delivery in a local bath;
- Batteries 12V 12À/hr with recharger;
- Transport and protective bag.
|
At starting |
Differential characteristic|
Field of utilization
Technical Characteristics
- The measuring block
- ultrasonic flaw detector UD2V-P46 / UD4-Ò
- Minimum defined water level
- up to 0,5mm
- Locality of the testing
- 5 mm
- Productivity of the testing
- 0,5-2 square meter/hr
- Admissible inclination of the cellular unit
- up to 30
- Height of an arrangement of the cellular unit
- not less than 1,5-2 m from floor level (the lift, a step-ladder and etc.))
- Operating temperature
- up to +5 to +55C
Are admissible uses at lower temperatures at air heating
by air field heaters of type of MT-300/MT-85 and use in
quality immersion liquids of 50 % of a solution of spirit and water
- Mains power
- by flaw detector- from a network 220V, or 4 accumulators "D"
Pump - 27V DÑ/220V AC or from the accumulator 9-12V
- Operating time
- not less than 8 hours
At starting |
Differential characteristic |
Field of utilization
|